Nebula 5V300A/450A/600A Regenerative Battery Cell Cycle Test System

The Nebula 5V300A/450A/600A Regenerative Battery Cell Cycle Test System is a computer‑controlled regenerative power test system. It is used for electrical performance testing of high‑power secondary batteries (traction and energy storage types), covering cycle life, capacity, DCIR, charge/discharge characteristics, deep discharge, consistency, and rate tests, with integrated data monitoring throughout the process.

Scope of Application

  • Consumer Battery
    Consumer Battery
  • Power Battery
    Power Battery
  • Energy Storage Battery
    Energy Storage Battery
  • 图片1-1

Product Feature

  • High‑precision control

    High‑precision control

    Voltage accuracy: ±0.02% F.S.

  • Deep discharge capability

    Deep discharge capability

    Discharge voltage down to 1 V

  • High‑rate battery testing

    High‑rate battery testing

    Parallel current up to 4800 A

  • Comprehensive charge/discharge protection

    Comprehensive charge/discharge protection

    Reduces the risk of battery production incidents

5-Range Automatic Current Grading

  • Voltage Accuracy:±0.02F.S.

    Current Accuracy:±0.03F.S.

图片14

10 ms Real-time Driving Profile

  • Capturing Precise Load Variations
    Quickly captures rapid changes in driving scenarios, providing precise data for optimizing battery performance.
图片15

Support Driving Profile Simulation 20 ms

Precisely replicates dynamic driving scenarios to provide accurate data for battery performance testing.

block431

Built-in Ripple Injection

The device self-generates and injects ripple signals internally

allowing a single charge/discharge channel to perform both charging and discharging with superimposed ripple

without the need for external ripple equipment

  • 纹波1
  • 纹波2
Deep Discharge Capability

  • Power supply side:Charging voltage 0~6V;Discharging voltage 0.6~6V
  • Cell side:Charging voltage: 0~5V;Discharging voltage:1~5V
图片9
图片11
Modular Design

Current Scalable up to 4800 A

  • Quick replacement and easy maintenance
  • Further upgrades without high cost
  • Clean and neat interior
  • Saves valuable floor space
Global Protection

For Worry-Free Operation

  • Voltage/current/up/down limit/grid over/under voltage/capacity up/down limit protection
  • Equipment power failure renewal protection
  • Channel abnormal capture protection
  • Battery reverse connection protection
  • Self-diagnostic protection
  • Overheating protection
  • Traceable protection logs
block501
图片1

Basic Parameter

  • BAT-NED-05300LX-V004
  • BAT-NED-05450LX-V004
  • BAT-NED-05600LX-V004
  • Voltage Range0V~5V; 1V~5V
  • Current Range0~300A
  • Voltage Accuracy±0.02% F.S.
  • Current Accuracy±0.03% F.S.
  • Current Range Accuracy50A/100A/200A/300A
  • Current Rise/Fall≤4ms
  • Driving Profile Simulation8ms
  • Sampling Rate20ms
  • Voltage Range0V~5V; 1V~5V
  • Current Range0~450A
  • Voltage Accuracy±0.02% F.S.
  • Current Accuracy±0.03% F.S.
  • Current Range Accuracy50A/100A/200A/300A/450A
  • Current Rise/Fall≤5ms
  • Driving Profile Simulation10ms
  • Sampling Rate20ms
  • Voltage Range0V~5V; 1V~5V
  • Current Range0~600A
  • Voltage Accuracy±0.02%F.S.
  • Current Accuracy±0.03%F.S.
  • Current Range Accuracy50A/100A/200A/300A/600A
  • Current Rise/Fall≤5ms
  • Driving Profile Simulation10ms
  • Sampling Rate20ms