Nebula 100V60A

Nebula Battery Module Cycle Test System

The Nebula battery module cycle test system integrates cycle charging/discharging, battery pack functional testing, and charge-discharge data monitoring capabilities, specifically designed for high-power battery packs including electric vehicle lithium battery modules, e-bike lithium battery packs, power tool lithium battery packs, and energy storage lithium battery packs. The system provides outstanding accuracy and flexibility throughout testing procedures, with the unique capability of feeding discharged energy back into the grid, helping enterprises achieve cost reduction and efficiency improvement.

Scope of Application

  • E-Bike
    E-Bike
  • EV
    EV
  • Energy Storage Battery
    Energy Storage Battery
  • Garden Equipment
    Garden Equipment
  • Power Tool
    Power Tool
  • 微信图片_20250109111044

Product Feature

  • High Precision

    High Precision

    ±0.05% F.S. current/voltage accuracy

  • Fast Response

    Fast Response

    Current response ≤ 5ms

  • Modular Design

    Modular Design

    Independent channel control

  • Offline Operation

    Offline Operation

    Up to 12 hours offline operation

  • Cost-Efficient

    Cost-Efficient

    Energy recovery > 91.3%

Modular Design with 16 Channels

Independent Control for Each Channel

  • 16-Channel Modular Design

  • Easy Scalability with Parallel Connections
  • Stable Performance with Easy Maintenance
  • Highly Integrated Design to Reduce Cabling Costs
  • More precise R&D and production testing: Voltage Accuracy ±0.05% F.S.
BAT-NEM-10060-V006-03
Energy Regenerative Efficiency > 91.3%

DC Bus Design Enables Energy Transfer from Channel to Channel

  • Regenerative energy from the discharging battery is recycled through the DC bus to other channels, cutting energy consumption and reducing operational costs.
BAT-NEM-10060-V006-04
≤5ms High-Speed Current Rise

  • Supports All High-Speed Dynamic Testing Requirements
BAT-NEM-10060-V006-05
Less Space, More Output Only 0.66
BAT-NEM-10060-V006-06_副本
微信图片_20250109111044

Basic Parameter

  • BAT-NEM-10060-V006, BAT-NEM-10060-V006-US (supports 480VAC ±10%)
  • Input Power380VAC ±10%, Frequency 50Hz/60Hz ±2Hz
  • Power Factor≥0.99 (full load)
  • Total Harmonic Distortion (THD)≤5% (full load)
  • Isolation MethodAC-DC high-frequency isolation
  • Input ProtectionSurge protection, islanding protection, over/under frequency protection, over/under voltage protection, phase loss protection, AC short circuit protection
  • DC Side Channels16 channels per cabinet (Max)
  • Single Channel Input Impedance≥1MΩ
  • Voltage Range (DC)Charging: 3.3V - 100V @60A; Discharging: 6.5V - 100V @60A; Discharging: 5V @13A
  • Voltage Output Accuracy±0.05% F.S.
  • Total Output Power80kW / 75kW / 60kW / 45kW / 30kW / 15kW (optional)
  • Operating Temperature0°C - 45°C
  • Dimensions660mm (W) * 1000mm (D) * 1810mm (H)
  • WeightApprox. 400kg
Write your message here and send it to us